This table summarizes the many systems in which biofilms form with undesirable
consequences. |
| System |
Impact
of Biofilm Formation |
References |
| Toilet
bowls |
Cosmetic
degradation |
Pitts et
al., Biofouling 13:19 (1998) |
| Cooling
water towers |
Reduced
heat and mass transfer |
Mortensen
and Conley, CTI J. 15:10 (1994) |
| Heat
exchangers |
Reduced
heat transfer |
|
| Paper manufacture |
Degradation of product quality |
Vaisanen
et al., J. Appl. Microbiol. 84:1069 (1998)
Robertson, TAPPI, Reprint 566 (1992)
Holt, in Biodeterioration
7, p. 493 (1987)
|
| Food processing |
Contamination |
Carpentier and Cerf, J. Appl. Bacteriol. 75:499 (1993)
Matilla-Sandholm and Wirtanen, Food
Rev. Int. 8:573 (1992) |
| Metalworking |
Degradation
of metalworking fluid |
Leder, Lubr.
Engr. 45:217 (1989) |
| Photo
processing |
Flawed
prints, machine failure |
Elvers et
al., J. Appl. Microbiol. 84:607 (1998) |
| Reverse osmosis |
Reduced
membrane permeability, material
degradation |
McDonogh et al., J. Membr. Sci. 87:199 (1994) |
| Swimming
pools |
Health
risks, cosmetic degradation |
|
| Household
drains |
Slow
draining sinks |
|
| Process
equipment |
Corrosion
and biodeterioration |
|
| Secondary oil recovery |
Plugging
of water injection wells, souring (hydrogen sulfide production) and corrosion |
|
| Drinking water pipes |
Health risks |
LeChevallier
et al., Appl. Environ. Microbiol. 62:220 (1996)
Camper, in Biofouling and Biocorrosion in
Industrial Water Systems, Ch. 6 (1994) |
| MEDICAL INFECTIONS |
|
|
| General |
Persistent infections |
Costerton et al., Science
284:1318-1322 (1999)
Potera, Science 283:1837 (1999)
|
| Dental
plaque |
Caries,
Gingivitis,
Periodontitis |
Marsh and Bradshaw, J. Ind. Microbiol. 15:169 (1995)
Darveau et al, Periodontol 2000 14:12 (1997)
Page et al, Periodontol 2000 14:216
|
Implanted devices
- contact lens
- urinary catheter
- vascular catheter
- central venous catheter
- Hickman catheter
- Swan-Ganz catheter
- periotoneal dialysis (Tenckhoff) catheter
- biliary stent
- orthopedic device
- prosthetic heart valve
- cardiac pacemaker
- IUD
- endotracheal tube
- nasogastric tube
- hemodialysis units
|
Persistent infections
Endocarditis
Contamination
Drain blockage |
Khardori and Yassien, J. Ind. Microbiol. 15:141 (1995)
Nickel et al, J. Antimicrob. Chemother. 33A:31 (1994)
Nickel, Can. J. Infect. Control 6:38 (1991)
Cox et al, Br. J. Urol. 64:395 (1989)
Nickel et al, Urology 34:284 (1989)
Ramsay et al, Br. J. Urol. 64:395 (1989)
Nickel et al, Can J. Surg. 28:50 (1985)
Gorman et al, Epidemiol. Infect. 112:551 (1994)
Giangrande et al, Perit. Dial. Int. 13(S2): S133 (1993)
Read et al, Kidney Int. 35:614 (1989)
Hyde et al, J. Heart Valve Dis. 7:316 (1998)
Marrie et al, Circulation 66:1339 (1982)
Feldman et al, Eur. Respir. J. 13:546 (1999)
Gorman et al, Eur. J. Clin. Microbiol. Dis. 12:9 (1993)
Sottile et al, Crit. Care Med. 14:265 (1986)
Phillips et al, J. Hosp. Infect. 27117 (1994)
Phillips et al, J. Hosp. Infect. 21:193 (1992)
|
Chronic infections
-otitis media
-cystic fibrosis pneumonia
-biliary tract infections
-osteomyelitis
-bacterial prostatitis
-native heart valve
|
Persistent infections |
Potera, Science 283:1837 (1999)
|